I stripped the old drive apart today. These so-called Medallist Seagate drives are fitted with a rubber protective jacket, which makes them more difficult to get at but, after a bit of thought, I found a way to remove it without risk of tearing it: I inserted a plastic ruler between the jacket and the top of the drive mechanism to break the bond which had formed between them and removed it by carefully slipping the corners from one side and pulling it away towards the other. I am confident that it will be possible to replace it again intact. Next, I removed the three Torx (T-8) screws securing the pcb and immediately the board came loose. Two sets of contacts protruding from the drive mechanism make electrical connection with the pcb via pads in two clusters on the underside of the board - one of three pads, designated J7, and another of eighteen, designated J1 - when the pcb is screwed down. If the drive electronics have failed, there is no visual indication of it, but that's not unusual. It just remains now to strip the new drive, swap the pcbs and, if I'm lucky, salvage the lost data, and I'm hoping to get this done tomorrow with photographs. |
25 June 2013, 00:50 | #23 |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
When this drive failed, it wouldn't even spin up after restarting the machine.
However, when fitted with the new pcb it does spin up, but it still fails to initialize, and no movement of the drive heads is evident. I am beginning to think that both the drive mechanism and electronics may be damaged, so I'm reluctant to try the new drive mechanism fitted with the original pcb in case it too should suffer damage. If it makes any difference, I did notice that the original drive and new drives have different firmware versions (the original has version 3.03 firmware and the new one version 3.32), otherwise they appear to be practically identical. I bought another of these drives from eBay last night after I had discovered how easily they can be disassembled, and it was dispatched this morning, so I will soon have another pcb to try with it. If the content of the original drive is lost, then I will recreate it as far as possible on one of the new drives and mirror that with the other drive to prevent this happening again. After all, these drives now cost an order of magnitude less than the original drive did ten years ago when it was new. Whatever the outcome, I will still upload some pictures if anyone is interested. Edit: If the original drive mechanism is damaged, it hasn't had a detrimrental effect on the new pcb, because the new drive still works fine when fitted with it. (I have been taking anti-static precautions throughout. ) Last edited by prowler; 25 June 2013 at 01:06. |
25 June 2013, 02:19 | #24 | |
Registered User
Join Date: Jul 2005
Location: Australia
Age: 46
Posts: 666
|
Quote:
If you choose to take my advice and the drive contents are really important to you (which I suspect is not the case otherwise you would simply replace it and restore from backups) then get in touch with Scott Moulton at myharddrivedied.com, a guy who is helpful and very well informed when it comes media recovery. The tone of this post may seem harsh but previous posters have quite innocently given you poor advice to the point where I had to step in. Best of luck and please remember The Tao Of Backup. |
|
25 June 2013, 22:16 | #25 | |||
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
It might not look like it occasionally, but - trust me on this - I do know what I'm doing. If the different firmware revisions have caused by first attempt to fail, I am quite sure that it won't mean catastrophic failure in the event of a subsequent attempt with another pcb. Thanks for the link to the success story, it looks very interesting! Quote:
Hands-on help from a third-party is out of the question, because the drive contains confidential material. Quote:
|
|||
26 June 2013, 00:09 | #26 |
Registered User
Join Date: Apr 2011
Location: birmingham
Age: 55
Posts: 2,827
|
will you be trying it again prowler?
|
26 June 2013, 00:42 | #27 |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Yes, mate. I've bought another Seagate ST38410A drive from eBay, which should arrive on Thursday or Friday this week, and then I'll have another go.
I have no idea what caused this drive to fail. I got no warning whatsoever. One moment I was editing a text file with Notepad in Windows, and then, when I tried to save the file, I got a blue screen with the message that Windows could not write to the hard drive. I assumed that there was insufficient space left on the drive to save the file, so I reset the machine with a boot disk in the floppy drive intent on deleting one or more files to make room, but the Primary Hard Drive failed when it tried to reboot! When it spins up on the new pcb I tried it with yesterday, it makes no unusual noises, but there is no evidence of head movement at any time prior to the "Primary Master Hard Disk Fail" message after the POST, but the new drive mechanism still works fine when fitted with it. I know that the original pcb is fried because the drive doesn't spin up when fitted with that board. However, if the drive mechanism is damaged too, then that will be the first time I have encountered that problem, so I am reluctant to give it up without at least one more try. |
26 June 2013, 09:15 | #28 |
Registered User
Join Date: Apr 2011
Location: birmingham
Age: 55
Posts: 2,827
|
even with different firmwares you should at least hear the heads move when the motor starts up.
maybe the heads are stuck. |
26 June 2013, 23:49 | #29 | |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
Maybe they are, but then I can't imagine what might have caused it, unless the drive electronics failure - as well as interrupting the motor supply - also sent the heads slamming against the end stop in an attempt to park them and they are now stuck there. Thinking these sort of things is what's stopping me from trying the new drive mechanism with the old pcb. If the drive I'm expecting in the next couple of days doesn't provide a solution, then I might try to unstick the heads by gently shocking the drive in a direction parallel with the platters. Would you happen to know if the drive heads park towards the centre or edge of the platters? Though I suppose they could be stuck anywhere, really. Why don't hard drives have transparent lids? |
|
27 June 2013, 01:07 | #30 | ||
Registered User
Join Date: Jul 2005
Location: Australia
Age: 46
Posts: 666
|
A drive with "stuck" heads won't spin at all, this may just be a difference in terminology though as the term normally refers to stiction, I'm sure this is what prowler means and it simply doesn't happen with modern drives.
Quote:
Quote:
http://en.wikipedia.org/wiki/Hard_disk_drive_failure http://www.techarp.com/showarticle.aspx?artno=84&pgno=0 |
||
27 June 2013, 01:28 | #31 | |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
Hey, I'm not looking to become a hard drive guru here, you know. If I can't find a simple DIY fix for this drive in order to recover the data, I'll just replace it with the new units(s) instead. |
|
27 June 2013, 12:26 | #32 |
Registered User
Join Date: Apr 2011
Location: birmingham
Age: 55
Posts: 2,827
|
nah, im not talking about stiction some drives heads get stuck on the stopper ive seen this before,some even have a mechanical arm that releases the heads after the motor reaches speed ive seen that fail.
i all honesty,prowler wants to investigate the drive himself and fairplay to him. it is after all his drive and he really has nothing to loose but data on a already faulty drive. say for instance,prowler wanted to take the top of the drive to have a look inside,peaple could say stop there dont do that but he may go ahead and have a look anyway it is his drive. Last edited by roy bates; 27 June 2013 at 12:35. |
27 June 2013, 22:02 | #33 | ||
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
Quote:
Eventually, I will open it to satisfy my curiosity, but I'll leave it until I have recreated the lost data as far as possible just in case I get a brainwave in the meantime. After all, once I open the drive the data will be gone for good. |
||
28 June 2013, 14:33 | #34 |
Registered User
Join Date: Feb 2012
Location: Staffordshire
Posts: 119
|
You could try Spinrite it takes a long time to work but I have managed to resurrect some drives with it.
https://www.grc.com/spinrite.htm Spinrite Demo on Youtube [ Show youtube player ] More info at link below http://www.diydatarecovery.nl/DiskPatch.htm |
28 June 2013, 21:06 | #35 | |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
The other hard drive I bought from eBay arrived today and, again, it's a good one, but it has the same firmware revision as the last - v3.32 - so I've decided not to try it on the faulty drive mechanism. Instead, I've decided to restore the partial backups to it as a first step towards recreating the content of the original, faulty drive. If I do have any success with the old drive by trying to shock the heads into life, then I'll certainly consider Spinrite as a means of recovering the lost data if necessary. |
|
28 June 2013, 23:30 | #36 |
Registered User
Join Date: Feb 2012
Location: Staffordshire
Posts: 119
|
Oh I see the actual drive wont detect.
As a last resort If you just want to recover the data old drives will still operate if you open them them up, obviously not recommended as they are made in clean room and some dust will get in. You could even swap the platters over and put them into the known working drive using gloves, if it exactly the same model it should work. |
29 June 2013, 01:26 | #37 | |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
Therefore, if I decide to try and swap platters or disk heads with another drive mechanism, it will have to be from yet another similar drive unit. I've already had a look for a suitable one on eBay, but there isn't one I'm willing to buy at the moment... Edit: On the other hand, OddbOd supplied a link to these 'myths' above:
However, there's no harm in trying the third method, I suppose, strictly as a last resort, though I'm not going to try shocking the heads back to life with the power applied. But first I must discover what is preventing the drive from spinning up when it's attached to the old pcb, and possibly fixing that will actually fix the drive! |
|
05 August 2013, 23:21 | #38 |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
I had a few spare moments earlier this evening, so I tried to get my original, faulty hard drive mechanism working with the pcb from the second replacement unit I bought from eBay, but the result was exactly the same as with the first replacement pcb I fitted.
Both replacement hard drives are now reassembled and fully working. When I've recreated the content of the original drive on one of these units as far as I am able, I'm going to mirror it with the other one! Unfortunately, the original drive mechanism will have to be be destroyed. |
06 August 2013, 02:53 | #39 |
Amiga user since 1990
Join Date: Aug 2004
Location: Kingsport, TN / USA
Age: 44
Posts: 295
|
|
06 August 2013, 21:42 | #40 | |
Global Moderator
Join Date: Aug 2008
Location: Sidcup, England
Posts: 10,300
|
Quote:
I do have one good thing to report, though: I had just completed backing it up! How lucky is that? However, having returned the machine back to standard configuration, that hard drive failed when I next booted it up. It could be that the secondary hard drive controller has failed; the DVD-ROM drive on that channel wasn't detected either. But I'm inclined to think it might be the PSU. It's difficult to test all the supply voltages with the machine fully assembled in its desktop case, so I've decided that tomorrow I will strip the machine completely apart, give everything a good clean and then test the PSU to start with, repair or replace it if necessary and then refit everything back in the case, powering it up and checking each component as I go. This is my main emulation machine, so it's vital that I get it fully working again soon. I have a great selection of spares, including two identical motherboards, so I'm hoping it's only a matter of time and patience. |
|
Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
Thread Tools | |
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
A590 and 4gb hard drive | 2E0TMF | support.Hardware | 41 | 04 January 2011 06:01 |
4GB CF IDE HARD DISK www.amigakit.com | amigakit.com | MarketPlace | 0 | 22 September 2010 14:24 |
4GB CF IDE HARD DRIVE www.amigakit.com | amigakit.com | MarketPlace | 29 | 09 August 2010 19:02 |
after a 4gb 2.5" hard drive | CU_AMiGA | MarketPlace | 9 | 02 March 2008 19:17 |
6.4Gb Hard Drive in winuae | pvt_beano | support.WinUAE | 2 | 19 January 2006 10:05 |
|
|