Quote:
Originally Posted by AMIGASYSTEM View Post
Sorry Toni I was wrong video i attach the right one (old age, 63 years old)

Ask what i never understood: With 060 JIT what is meant by CPU Internal and More Compatible?
This video also shows unticked JIT FPU checkbox ("FPU Support" in Advanced JIT settings)

CPU Internal = FPU is CPU built-in. 68881/68882 are external FPUs for 68020/68030. 68040/060 can't use external FPUs.

More compatible enables more strict rounding rules (and slower) and normal FPU modes (It has no effect on softfloat). Most programs don't care.