Quote:
Originally Posted by Locutus View Post
Just out of curiosity, is it possible to have the Cyberstorm's SCSI controller to appear at its original location but while emulating a BPPC board without SCSI? A perverse non-existing hybrid.

Probably that still requires one to move some modules around inside of the boot image, no idea of its layout but one would guess thats doable.
CSPPC and BPPC SCSI is located in same address range (0xf4xxxx), swapping them would be very easy.

But does the module do any validation checks first? It is not going to work if it does any non-SCSI related checks like "Is this CSPPC board?"

EDIT: But BPPC boot ROM would hang/crash, you would need to remove BPPC SCSI driver from boot ROM, boot from IDE.. It is not going to be very useful..