Testing Supra A500 drive emulation I noticed a small issue when SupraHDTools issues a MODE SENSE command for page 3 (format device page):
raw_scsi: got command 1a (6 bytes)
1a.00.c3.00.ff.00.
SCSIEMU HD 0: 1A.00.C3.00.FF.00.00.00.00.00.00.00 CMDLEN=6 DATA=06806648
-> DATAOUT=36 ST=0 SENSELEN=0 REPLYLEN=36
REPLY: 23.00.00.08.00.00.A0.00.00.00.02.00.03.18.00.01.00.00.00.00.00.00.00.20.02.00.00.01.00.00.00.00.80.00.00.00.


The length field in the page data should be $16 not $18.

Edit: and should the tracks per zone field be 0000, not 0001?
And same length issue with page 4.